Specifications |
EIB 3392 S |
Functional safety |
Depending on the connected encoder and subsequent electronics, suited for applications up to
|
PFH |
26 · 10–9 (with respect to an operating altitude of ≤ 1000 m above sea level) |
Safe position |
Due to the connected encoder and the subsequent electronics (i.e. through the configuration); |
Input |
|
Interface |
EnDat 2.2 |
Ordering designation |
EnDat22 (Note the requirements on the encoder) |
Electrical connection |
Various connectors (see ''Versions of the EIB 3392 S”) |
Encoder supply voltage (UP2) |
DC 8.0 V ±0.4 V, max. 1800 mW |
Cable length |
≤ 30 m1) |
Output |
|
Interface |
DRIVE-CLiQ |
Ordering designation |
DQ01 |
Electrical connection |
Various connectors (see ''Versions of the EIB 3392 S”) |
Cable length |
≤ 30 m2) |
Voltage supply (UP1) |
DC 24 V (16.0 V to 28.8 V) |
Power consumption |
Maximum At 16.0 V: ≤ 3200 mW Typical At 24 V: 1000 mW + 1.15 x PMtyp |
Operating temperature |
0 °C to 60 °C |
Storage temperature |
–30 °C to 70 °C |
Vibration 55 Hz to 2000 Hz Shock 11 ms |
100 m/s2 (IEC 60 068-2-6) 200 m/s2 (IEC 60 068-2-27) |
Protection EN 60 529 |
IP653) |
Mass |
≈ 0,2 kg (with 1 m cable length on both sides) |
1) With HEIDENHAIN cable; note the power supply at the encoder. 2) Depending on the output cable; the plug connection to the EIB is to be considered a DRIVE-CLiQ coupling. 3) Use the correct connector version DRIVE-CLiQ is a registered trademark of SIEMENS AG. |