Scanning head |
AK ERO 6180 |
Interface |
1 VPP |
Reference mark signal |
Square-wave pulse |
Cutoff frequency –3 dB |
≥ 200 kHz |
Electrical connection |
Cable 3 m with D-sub connector (male), 15-pin |
Cable length |
≤ 30 m |
Voltage supply |
DC 5 V ±0.25 V |
Current consumption |
< 100 mA (without load) |
Vibration 55 to 2000 Hz Shock 6 ms |
≤ 200 m/s2 (EN 60 068-2-6) ≤ 500 m/s2 (EN 60 068-2-27) |
Operating temperature |
0 °C to 50 °C (32 °F to 122 °F) |
Mass Scanning head Connector Cable |
≈ 6 g (without cable) ≈ 32 g ≈ 22 g/m |
Circular scale |
TKN ERO 6100 |
Measuring standard |
Chrome graduation on glass |
Signal periods |
4096 |
Accuracy of graduation |
±10” |
Interpolation error per signal period1) |
±5” |
Reference marks |
One |
Hub inside diameter |
41 mm |
Circular scale outside diameter |
70 mm |
Mech. permissible speed |
≤ 3500 rpm |
Moment of inertia |
50 x 10–6 kgm2 |
Permissible axial motion |
≤ 0.1 mm |
Protection EN 60 529 |
Complete encoder in mounted position: IP00 |
Mass |
≈ 71 g |
1) Interpolation error within one signal period and the accuracy of the graduation together result in the encoder-specific error; for additional error from mounting and bearing of the measured shaft, see Measuring accuracy |