TS 248/TS 260

  • Specifications
  • Documentation
Specifications

Cable

Workpiece touch probe

TS 248

TS 260

TS 150

Probe accuracy

±5 µm with use of the T404 standard stylus

Probe repeatability

Repeated probing from one direction

2 s 1 µm at a probing velocity of 1 m/min

Typical values:

2 s 1 µm at a probing velocity of 3 m/min

2 s 4 µm at a probing velocity of 5 m/min

Deflection of probe contact

5 mm in all directions (with stylus length L = 40 mm)

Deflection forces

Axial:  8 N (TS 248:  4 N)

Radial:  1 N (TS 248:  0.5 N)

Probing velocity

5 m/min

Protection EN 60529

IP68

Operating temperature

10 °C to 40 °C

Storage temperature

–20 °C to 70 °C

Mass without taper shank

 0.15 kg

 0.1 kg

Fastening*

  • With taper shank1) (only with radial flange socket)
  • Via M28x0.75 external thread
  • Via coupling joint with M22x1 external thread
  • Via M16x1 external thread on the mounting base
  • Contact on the mounting base
  • Axial cable outlet: M22x1 for fastening to the machine
  • Radial cable outlet: Fastened to the machine with four M3 screws

Electrical connection*

8-pin M12 flange socket, axial or radial

Two-pole sliding contact on the mounting base

Cable length

25 m

Supply voltage2)

DC 15 V to 30 V/ 100 mA (without load)

DC 15 V to 30 V/ 85 mA (without load)

Output signals2)

  • Trigger signals S and S (square-wave signal and its inverted signal)
  • Floating trigger output

HTL signal levels2)

UH 20 V at –IH 20 mA

UL 2.8 V at IL 20 mA

at rated voltage of DC 24 V

Signal transmission

Cable

* Please select when ordering

1) See Mounting on page 18

2) With the TS 150: over the UTI 150