- Specifications
- Documentation
Scale |
LIF 401 R |
|||||
Measuring standard* Coefficient of linear expansion |
SUPRADUR phase grating on Zerodur glass ceramic or glass; grating period: 8 µm αtherm = (0±0.1) · 10–6 K–1 (Zerodur glass ceramic); αtherm 8 · 10–6 K–1 (glass) |
|||||
Accuracy grade |
±3 µm |
|||||
Baseline error |
≤ ±0.225 µm/5 mm |
|||||
Measuring length (ML)* in mm |
70 120 170 220 270 320 370 420 470 520 570 620 670 720 770 820 870 920 970 1020 1140 1240 1340 1440 1540 1640 |
|||||
Reference marks |
One at midpoint of measuring length |
|||||
Mass |
0.8 g + 0.08 g/mm of measuring length |
|||||
Scanning head |
LIF 48 V |
LIF 47 V |
||||
Interface |
1 VPP |
TTL |
||||
Integrated interpolation* Signal period |
– 4 µm |
5-fold 0.8 µm |
10-fold 0.4 µm |
20-fold 0.2 µm |
50-fold 0.08 µm |
100-fold 0.04 µm |
Cutoff frequency –3 dB |
≥ 1 MHz |
– |
||||
Scanning frequency* |
– |
≤ 500 kHz ≤ 250 kHz ≤ 125 kHz |
≤ 250 kHz ≤ 125 kHz ≤ 62.5 kHz |
≤ 250 kHz ≤ 125 kHz ≤ 62.5 kHz |
≤ 100 kHz ≤ 50 kHz ≤ 25 kHz |
≤ 50 kHz ≤ 25 kHz ≤ 12.5 kHz |
Edge separation a |
– |
≥ 0.080 µs ≥ 0.175 µs ≥ 0.370 µs |
≥ 0.080 µs ≥ 0.175 µs ≥ 0.370 µs |
≥ 0.040 µs ≥ 0.080 µs ≥ 0.175 µs |
≥ 0.040 µs ≥ 0.080 µs ≥ 0.175 µs |
≥ 0.040 µs ≥ 0.080 µs ≥ 0.175 µs |
Traversing speed1) |
≤ 240 m/min |
≤ 120 m/min ≤ 60 m/min ≤ 30 m/min |
≤ 60 m/min ≤ 30 m/min ≤ 15 m/min |
≤ 60 m/min ≤ 30 m/min ≤ 15 m/min |
≤ 24 m/min ≤ 12 m/min ≤ 6 m/min |
≤ 12 m/min ≤ 6 m/min ≤ 3 m/min |
Interpolation error RMS position noise |
±12 nm 0.6 nm (1 MHz2)) |
– |
||||
Electrical connection* |
|
|||||
Cable length |
See interface description; however, |
|||||
Supply voltage |
DC 5 V ±0.25 V |
|||||
Current consumption |
< 150 mA |
< 165 mA (without load) |
||||
Vibration 55 Hz to 2000 Hz Shock 11 ms |
≤ 400 m/s2 (EN 60068-2-6) ≤ 500 m/s2 (EN 60068-2-27) |
|||||
Operating temperature |
0 °C to 50 °C |
|||||
Baking temperature |
100 °C |
|||||
PCB material |
FR4 |
|||||
Mass Scanning head Cable Connector |
9 g 38 g/m 75 g |
|||||
* Please select when ordering 1) With TTL: maximum traversing speed during referencing: 9.6 m/min (40 kHz) 2) –3 dB cutoff frequency of subsequent electronics |